Wind & airflow laboratory
An energy-conserving, lumped-parameter laboratory for engineering students—not a computational fluid dynamics solver.
Incoming airflow
Uniform incoming flow: rotor position changes the illustration, not wind power. Saved turbine parameters are shared.
Idealized wind turbine
Educational approximationWind velocity & electrical power
Horizontal axis: slider 0–100%. These are calculated operating points, not measured time-series data.
Energy conversion & governing equations
1.92 kW
770 W
654 W
A = π(D/2)² = 3.14 m²
Pavailable = ½ρA|v|³
Cp,effective = Cp × max(0, cos pitch)²
Pmechanical = Cp,effective × Pavailable
Pelectrical = η × Pmechanical
ω = sign(v)√(Pmechanical / (B + Bload))
T = Pmechanical / ω; B = 0.02 N·m·s/rad
ρ is air density; A is swept area; v is uniform wind speed; Cp is power coefficient bounded by the Betz limit 16/27; η is generator efficiency. The viscous equilibrium gives steady-state speed, not startup dynamics. Pitch is a declared cosine-squared approximation; Cp is not a blade-performance curve.